Title |
Dimensional stability and surface hardness of inter-occlusal recording materials
|
Authors |
Khyati N. Gosai1, Ina B. Patel2, Pooja Poonia3, Bhagyashree Sutaria4, Mahima Trivedi5 & Sarita Mori6,*
|
Affiliation |
1Department of Prosthodontics Crown and Bridge, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, Rajasthan, India; 2Department of Prosthodontics Crown and Bridge, AMC Dental College and Hospital, Ahmedabad, Gujarat, India; 3Department of Prosthodontics Crown and Bridge, Ahmedabad Dental College, Ahmedabad, Gujarat, India; 4Department of Prosthodontics Crown and Bridge, Siddhpur Dental College and Hospital, Gujarat, India; 5Dental Studio, Vadodara, Gujarat, India; 6Department of Periodontology, Ahmedabad Dental College, Ahmedabad, Gujarat, India; *Corresponding author
|
|
Khyati N. Gosai - E-mail: khyati05_gosai@yahoo.com; Phone: +91 9558886299; Ina B. Patel - E-mail: patel_ina@yahoo.in; Phone: +91 9879820783 Pooja Poonia - E-mail: poojapoonia012@gmail.com; Phone: +91 7600880826 Bhagyashree Sutaria - E-mail: bhagyadave91@gmail.com; Phone: +91 9723816915 Mahima Trivedi - E-mail: drmahimat18@gmail.com; Phone: +91 9909987669 Sarita Mori - E-mail: dr.saritabmori@gmail.com; Phone: +91 7383632412 |
Article Type |
Research Article
|
Date |
Received April 1, 2024; Revised April 30, 2024; Accepted April 30, 2024, Published April 30, 2024
|
Abstract |
It is important to choose the appropriate interocclusal registration material for precise articulation and successful dental prosthesis fabrication. 3 types of interocclusal registration materials: Bite registration wax, polyvinyl siloxane bite registration paste and Bisacryl-based bite registration paste were evaluated for dimensional stability and surface hardness at 4 different time intervals. One way ANOVA test, multiple Post Hoc Tukey HSD test and nonparametric test were performed. Bisacryl-based bite registration material exhibited better dimensional stability and surface hardness than polyvinyl siloxane and bite registration wax at all 4 time intervals. Thus dimensional stability and surface hardness of interocclusal registration material was influenced by both the type of material and the time duration.
|
Keywords |
Inter-occlusal registration materials, bisacrylate luxabite, polyvinyl siloxane, aluwax
|
Citation |
Gosai et al. Bioinformation 20(4): 344-348 (2024)
|
Edited by |
Swati Kharat
|
ISSN |
0973-2063
|
Publisher |
|
License |
This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.
|
|