HOME   |    PDF   |   


Title

Dimensional stability and surface hardness of inter-occlusal recording materials

 

Authors

Khyati N. Gosai1, Ina B. Patel2, Pooja Poonia3, Bhagyashree Sutaria4, Mahima Trivedi5 &

Sarita Mori6,*

 

Affiliation

1Department of Prosthodontics Crown and Bridge, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, Rajasthan, India; 2Department of Prosthodontics Crown and Bridge, AMC Dental College and Hospital, Ahmedabad, Gujarat, India; 3Department of Prosthodontics Crown and Bridge, Ahmedabad Dental College, Ahmedabad, Gujarat, India; 4Department of Prosthodontics Crown and Bridge, Siddhpur Dental College and Hospital, Gujarat, India; 5Dental Studio, Vadodara, Gujarat, India; 6Department of Periodontology, Ahmedabad Dental College, Ahmedabad, Gujarat, India; *Corresponding author

 

Email

Khyati N. Gosai - E-mail: khyati05_gosai@yahoo.com; Phone: +91 9558886299;

Ina B. Patel - E-mail: patel_ina@yahoo.in; Phone: +91 9879820783

Pooja Poonia - E-mail: poojapoonia012@gmail.com; Phone: +91 7600880826

Bhagyashree Sutaria - E-mail: bhagyadave91@gmail.com; Phone: +91 9723816915

Mahima Trivedi - E-mail: drmahimat18@gmail.com; Phone: +91 9909987669

Sarita Mori - E-mail: dr.saritabmori@gmail.com; Phone: +91 7383632412

 

Article Type

Research Article

 

Date

Received April 1, 2024; Revised April 30, 2024; Accepted April 30, 2024, Published April 30, 2024

 

Abstract

It is important to choose the appropriate interocclusal registration material for precise articulation and successful dental prosthesis fabrication. 3 types of interocclusal registration materials: Bite registration wax, polyvinyl siloxane bite registration paste and Bisacryl-based bite registration paste were evaluated for dimensional stability and surface hardness at 4 different time intervals. One way ANOVA test, multiple Post Hoc Tukey HSD test and nonparametric test were performed. Bisacryl-based bite registration material exhibited better dimensional stability and surface hardness than polyvinyl siloxane and bite registration wax at all 4 time intervals. Thus dimensional stability and surface hardness of interocclusal registration material was influenced by both the type of material and the time duration.

 

Keywords

Inter-occlusal registration materials, bisacrylate luxabite, polyvinyl siloxane, aluwax

 

Citation

Gosai et al. Bioinformation 20(4): 344-348 (2024)

 

Edited by

Swati Kharat

 

ISSN

0973-2063

 

Publisher

Biomedical Informatics

 

License

This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.