Title |
Marginal bone loss around axial and straight
implants supported with prefabricated SFI-Bar with mandibular
overdentures
|
Authors |
Prema Balehonnur, Vaibhav Nandakumar
Awinashe, Anuj Singh Parihar, Doddy Lokanathan Balaji, Anuraj Singh
Kochhar, Rajat Mehndiratta
|
Affiliation |
1Department of Prosthodontics, Government dental college and research Institute, Bangalore, Karnataka, India; 2Department of Prosthodontics, College of dentistry in Ar Rass, Qassim University, Kingdom of Saudi Arabia; 3Department of Periodontology and Oral Implantology, Peoples Dental Academy Bhopal, MP, India; 4Department of Prosthodontics, Priyadarshini Dental College and Hospital, Thiruvallur, 631203, India;
|
|
Dr. Prema Balehonnur - E-mail: dr.prema.162@gmail.com; Dr. Vaibhav Nandakumar Awinashe - E-mail: minalawinashe@gmail.com; Dr. Anuj Singh Parihar - E-mail: dr.anujparihar@gmail.com; Dr. Doddy Lokanathan Balaji - E-mail: lokanathan.balaji@gmail.com; Dr. Anuraj Singh Kochhar – E-mail: anuraj_kochhar@yahoo.co.in; Dr. Rajat Mehndiratta - E-mail:mehndirattajat@gmail.com; *Corresponding author; Dr. Anuj Singh Parihar - E-mail: dr.anujparihar@gmail.com, anilkk44@gmail.com
|
Article Type |
Research Article
|
Date |
Received January 10, 2020; Revised
January 30, 2020; Accepted January 31, 2020, Published January 31,
2021
|
Abstract |
To assess the role of prefabricated SFI-Bar in peri-implant bone loss around immediately axially loaded and straight implants. This study comprised of 40 complete denture wearer patients who received two axially parallel implants connected by SFI-Bars in group I and two 15° mesially tilted implants connected by SFI-Bars in group II. Peri- implant bone loss (PiBL) was measured at 1 year, 2 years and 3 years. The mean PiBL at 1 year in group I was 0.21 mm and I group II was 0.22, at 2 years in group I was 0.26 mm and in group II was 0.23 mm and at 3 years, in group I was 0.29 mm and in group II was 0.34 mm. The difference was significant at 3 years (P< 0.05). The mean mesial PIBL at 1year in group I was 0.18 mm, in group II was 0.20 mm, at 2 years in group I was 0.19 mm and in group II was 0.07 mm and at 3 years, in group I was 0.25 mm and in group II was 0.29 mm. The difference found to be significant in each time duration in both groups (P< 0.05).The mean distal PIBL at 1 year in group I was 0.23 mm, in group II was 0.22 mm, at 2 years in group I was 0.33 mm and in group II was 0.39 mm and at 3 years, in group I was 0.34 mm and in group II was 0.39 mm. The difference found to be significant at 2 and 3 years in both groups (P< 0.05). Authors found that mandibular overdentures retained with Prefabricated SFI-Bar with axial and straight inserted implants may be useful in patients with reduced bone height.
|
Keywords |
Axial; Implants; mandibular
overdentures.
|
Citation |
Balehonnur et al. Bioinformation 17(1):
289-294 (2021)
|
Edited by |
P Kangueane
|
ISSN |
0973-2063
|
Publisher |
|
License |
This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.
|
|